{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2026-19971 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-19971 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-19971 is a medium-severity missing authorization vulnerability in LB-Link WR1210M, published on 17 Aug 2026. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-19971 and fix it if it is affected.\n\nWhat it is: CVE-2026-19971 is a medium-severity missing authorization vulnerability in LB-Link WR1210M, published on 17 Aug 2026. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2026-19971 in the wild and no public exploit code.\n\nAffected product: LB-Link WR1210M. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-19971/ (Markdown: https://insights.sbomify.com/CVE-2026-19971/index.md)","id":"CVE-2026-19971","markdown":"https://insights.sbomify.com/CVE-2026-19971/index.md","name":"CVE-2026-19971","record":{"aliases":["GHSA-68gf-2fwf-ggrm"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["data_read","data_modify"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"LB-Link router","requires_auth":"none","summary":"An attacker on the local network can access the backup endpoint without authentication, potentially reading or modifying configuration data.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[],"cvss":{"score":5.3,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:L/SI:N/SA:N/E:X","version":"4.0"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"},{"id":"CWE-287","name":"Improper Authentication"}],"description":"A flaw has been found in LB-Link WR1210M 1.0.3. This impacts the function main of the file /www/cgi-bin/backup.cgi of the component Backup Endpoint. This manipulation causes missing authentication. The attack is only possible within the local network. The vendor was contacted early about this disclosure but did not respond in any way.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"LB-Link WR1210M Backup Endpoint backup.cgi main missing authentication","id":"CVE-2026-19971","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2026"},"n_packages":0,"n_references":4,"next":{"headline":"itsourcecode Hospital Management System viewpatient.php sql injection","id":"CVE-2026-19972"},"packages":[],"prev":{"headline":"Open Asset Import Library Assimp Node MDLLoader.cpp AddBonesToNodeGraph_3DGS_MDL7 heap-based overflow","id":"CVE-2026-19970"},"products":["WR1210M"],"published":"2026-08-17","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-08-17","vendors":["LB-Link"]},"summary":"An attacker on the local network can access the backup endpoint without authentication, potentially reading or modifying configuration data.","url":"https://insights.sbomify.com/CVE-2026-19971/"}