{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2026-20759 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-20759 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-20759 is a high-severity command injection vulnerability in TOA Corporation Multiple Network Cameras TRIFORA 3 series, published on 16 Jan 2026. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-20759 and fix it if it is affected.\n\nWhat it is: CVE-2026-20759 is a high-severity command injection vulnerability in TOA Corporation Multiple Network Cameras TRIFORA 3 series, published on 16 Jan 2026. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2026-20759 in the wild and no public exploit code.\n\nAffected product: TOA Corporation Multiple Network Cameras TRIFORA 3 series. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-20759/ (Markdown: https://insights.sbomify.com/CVE-2026-20759/index.md)","id":"CVE-2026-20759","markdown":"https://insights.sbomify.com/CVE-2026-20759/index.md","name":"CVE-2026-20759","record":{"aliases":["GHSA-gxjh-hg32-4hrj"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Network Camera","requires_auth":"low_privilege","summary":"A logged-in user with low privileges can execute arbitrary OS commands on TOA TRIFORA 3 network cameras.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"jpcert","cpe":[],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"}],"description":"OS Command Injection vulnerability exists in multiple Network Cameras TRIFORA 3 series provided by TOA Corporation, which may allow a logged-in user with the low(\"monitoring user\") or higher privilege to execute an arbitrary OS command.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Command injection in Multiple Network Cameras TRIFORA 3 series","id":"CVE-2026-20759","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2026"},"n_packages":0,"n_references":2,"next":{"headline":"Privilege escalation in Intel(R) Processors","id":"CVE-2026-20760"},"packages":[],"prev":{"headline":"Race condition in Command Centre Server","id":"CVE-2026-20757"},"products":["Multiple Network Cameras TRIFORA 3 series"],"published":"2026-01-16","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-01-16","vendors":["TOA Corporation"]},"summary":"A logged-in user with low privileges can execute arbitrary OS commands on TOA TRIFORA 3 network cameras.","url":"https://insights.sbomify.com/CVE-2026-20759/"}