{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2026-22096 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-22096 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-22096 is a critical missing authorization vulnerability in EVbee DC-80, published on 13 Jul 2026. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-22096 and fix it if it is affected.\n\nWhat it is: CVE-2026-22096 is a critical missing authorization vulnerability in EVbee DC-80, published on 13 Jul 2026. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2026-22096 in the wild and no public exploit code.\n\nAffected product: EVbee DC-80. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-22096/ (Markdown: https://insights.sbomify.com/CVE-2026-22096/index.md)","id":"CVE-2026-22096","markdown":"https://insights.sbomify.com/CVE-2026-22096/index.md","name":"CVE-2026-22096","record":{"aliases":["GHSA-56jh-x7v6-jq26"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["data_read","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"EVbee DC-80","requires_auth":"none","summary":"Unauthenticated access to the webserver allows attackers to leak sensitive passwords and upload files on the EVbee DC-80 device.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"DIVD","cpe":[],"cvss":{"score":9.3,"severity":"critical","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"description":"The webserver running on port 8090 does not require authentication. This allows for sensitive information leakage such as configured passwords, or uploading files through different endpoints.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Missing authentication for webserver endpoints","id":"CVE-2026-22096","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2026"},"n_packages":0,"n_references":1,"next":{"headline":"Missing firmware validation allows remote code execution","id":"CVE-2026-22097"},"packages":[],"prev":{"headline":"Command injection in diagnosis web endpoint","id":"CVE-2026-22095"},"products":["DC-80"],"published":"2026-07-13","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-07-16","vendors":["EVbee"]},"summary":"Unauthenticated access to the webserver allows attackers to leak sensitive passwords and upload files on the EVbee DC-80 device.","url":"https://insights.sbomify.com/CVE-2026-22096/"}