{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2026-22912 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-22912 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-22912 is a medium-severity vulnerability in SICK AG TDC-X401GL, published on 15 Jan 2026. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2026-22912 and fix it if it is affected.\n\nWhat it is: CVE-2026-22912 is a medium-severity vulnerability in SICK AG TDC-X401GL, published on 15 Jan 2026. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2026-22912 in the wild and no public exploit code.\n\nAffected product: SICK AG TDC-X401GL. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-22912/ (Markdown: https://insights.sbomify.com/CVE-2026-22912/index.md)","id":"CVE-2026-22912","markdown":"https://insights.sbomify.com/CVE-2026-22912/index.md","name":"CVE-2026-22912","record":{"aliases":["GHSA-xm6h-xrxm-vr76"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["account_takeover","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"SICK TDC-X401GL","requires_auth":"none","summary":"Attackers can redirect authenticated users to malicious sites via improper login parameter validation, risking credential theft on SICK TDC-X401GL devices.","user_interaction":"required","vuln_class":"open_redirect"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"SICK AG","cpe":[{"product":"tdc-x401gl_firmware","vendor":"sick"}],"cvss":{"score":4.3,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-601","name":"URL Redirection to Untrusted Site"}],"description":"Improper validation of a login parameter may allow attackers to redirect users to malicious websites after authentication. This can lead to various risk including stealing credentials from unsuspecting users.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Open redirect in TDC-X401GL","id":"CVE-2026-22912","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"open_redirect","year":"2026"},"n_packages":0,"n_references":6,"next":{"headline":"Cross-site scripting in TDC-X401GL","id":"CVE-2026-22913"},"packages":[],"prev":{"headline":"Information disclosure in TDC-X401GL","id":"CVE-2026-22911"},"products":["TDC-X401GL"],"published":"2026-01-15","related":[{"cvss_score":9.9,"headline":"Path traversal in TDC-X401GL","id":"CVE-2026-22907","kev_date_added":null,"published":"2026-01-15"},{"cvss_score":9.1,"headline":"File upload in TDC-X401GL","id":"CVE-2026-22908","kev_date_added":null,"published":"2026-01-15"},{"cvss_score":7.5,"headline":"Missing authorization in TDC-X401GL","id":"CVE-2026-22909","kev_date_added":null,"published":"2026-01-15"},{"cvss_score":7.5,"headline":"Hardcoded credentials in TDC-X401GL","id":"CVE-2026-22910","kev_date_added":null,"published":"2026-01-15"},{"cvss_score":5.3,"headline":"Information disclosure in TDC-X401GL","id":"CVE-2026-22911","kev_date_added":null,"published":"2026-01-15"},{"cvss_score":4.3,"headline":"Cross-site scripting in TDC-X401GL","id":"CVE-2026-22913","kev_date_added":null,"published":"2026-01-15"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-01-15","vendors":["SICK AG"]},"summary":"Attackers can redirect authenticated users to malicious sites via improper login parameter validation, risking credential theft on SICK TDC-X401GL devices.","url":"https://insights.sbomify.com/CVE-2026-22912/"}