{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2026-24105 exists.","fix":"No fix has been published for CVE-2026-24105 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-24105 is a critical command injection vulnerability in Tenda Ac15 Firmware, published on 2 Mar 2026. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-24105 and fix it if it is affected.\n\nWhat it is: CVE-2026-24105 is a critical command injection vulnerability in Tenda Ac15 Firmware, published on 2 Mar 2026. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2026-24105 exists.\n\nAffected product: Tenda Ac15 Firmware. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-24105/ (Markdown: https://insights.sbomify.com/CVE-2026-24105/index.md)","id":"CVE-2026-24105","markdown":"https://insights.sbomify.com/CVE-2026-24105/index.md","name":"CVE-2026-24105","record":{"aliases":["GHSA-r2xx-c2qg-8hph"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda AC15 router","requires_auth":"none","summary":"Attackers can execute arbitrary commands on Tenda AC15 routers via the formsetUsbUnload function due to insufficient input validation.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"ac15_firmware","vendor":"tenda"}],"cvss":{"score":9.8,"severity":"critical","source":"cisa-adp","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-94","name":"Improper Control of Generation of Code"}],"description":"An issue was discovered in goform/formsetUsbUnload in Tenda AC15V1.0 V15.03.05.18_multi. The value of `v1` was not checked, potentially leading to a command injection vulnerability if injected into doSystemCmd.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Command injection in n/a","id":"CVE-2026-24105","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"tenda:ac15_firmware","products":["tenda:ac15_firmware"],"type":"command_injection","year":"2026"},"n_packages":0,"n_references":2,"next":{"headline":"Command injection in n/a","id":"CVE-2026-24107"},"packages":[],"prev":{"headline":"Memory corruption in n/a","id":"CVE-2026-24103"},"products":["n/a"],"published":"2026-03-02","related":[{"cvss_score":9.8,"headline":"Tenda AC1900 Router AC15 Model Remote Code Execution","id":"CVE-2020-10987","kev_date_added":"2021-11-03","published":"2020-07-13"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2026-24103","kev_date_added":null,"published":"2026-03-03"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2026-24101","kev_date_added":null,"published":"2026-03-02"},{"cvss_score":9.8,"headline":"Information disclosure in n/a","id":"CVE-2025-63666","kev_date_added":null,"published":"2025-11-12"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-29462","kev_date_added":null,"published":"2025-04-03"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2025-25632","kev_date_added":null,"published":"2025-03-05"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"poc","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-03-03","vendors":["n/a"]},"summary":"Attackers can execute arbitrary commands on Tenda AC15 routers via the formsetUsbUnload function due to insufficient input validation.","url":"https://insights.sbomify.com/CVE-2026-24105/"}