{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2026-24441 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-24441 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-24441 is a high-severity vulnerability in Tenda Ac7 Firmware, published on 3 Feb 2026. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-24441 and fix it if it is affected.\n\nWhat it is: CVE-2026-24441 is a high-severity vulnerability in Tenda Ac7 Firmware, published on 3 Feb 2026. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2026-24441 in the wild and no public exploit code.\n\nAffected product: Tenda Ac7 Firmware. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-24441/ (Markdown: https://insights.sbomify.com/CVE-2026-24441/index.md)","id":"CVE-2026-24441","markdown":"https://insights.sbomify.com/CVE-2026-24441/index.md","name":"CVE-2026-24441","record":{"aliases":["GHSA-j785-3rj2-95j3"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["data_read","account_takeover"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda AC7 router","requires_auth":"none","summary":"An on-path attacker can intercept plaintext admin credentials from HTTP responses, leading to unauthorized access to the Tenda AC7 router.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulnCheck","cpe":[{"product":"ac7_firmware","vendor":"tenda"}],"cvss":{"score":8.2,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-319","name":"Cleartext Transmission of Sensitive Information"}],"description":"Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior expose account credentials in plaintext within HTTP responses, allowing an on-path attacker to obtain sensitive authentication material.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Tenda AC7 Transmits Admin Credentials Without HTTPS Protection","id":"CVE-2026-24441","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"tenda:ac7_firmware","products":["tenda:ac7_firmware"],"type":"information_disclosure","year":"2026"},"n_packages":0,"n_references":2,"next":{"headline":"This CVE ID has been rejected or withdrawn by its CVE Numbering Authority.","id":"CVE-2026-24442"},"packages":[],"prev":{"headline":"Tenda W30E V2 Allows Password Changes Without Verifying Current Password","id":"CVE-2026-24440"},"products":["Tenda AC7"],"published":"2026-02-03","related":[{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2026-51843","kev_date_added":null,"published":"2026-06-19"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2026-51844","kev_date_added":null,"published":"2026-06-19"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2026-51845","kev_date_added":null,"published":"2026-06-19"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2026-51846","kev_date_added":null,"published":"2026-06-19"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-29135","kev_date_added":null,"published":"2025-03-24"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-29137","kev_date_added":null,"published":"2025-03-19"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2024-32301","kev_date_added":null,"published":"2024-04-17"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-05-14","vendors":["Shenzhen Tenda Technology Co., Ltd."]},"summary":"An on-path attacker can intercept plaintext admin credentials from HTTP responses, leading to unauthorized access to the Tenda AC7 router.","url":"https://insights.sbomify.com/CVE-2026-24441/"}