{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2026-24790 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-24790 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-24790 is a high-severity missing authorization vulnerability in Welker OdorEyes EcoSystem Pulse Bypass System with XL4 Controller, published on 20 Feb 2026. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-24790 and fix it if it is affected.\n\nWhat it is: CVE-2026-24790 is a high-severity missing authorization vulnerability in Welker OdorEyes EcoSystem Pulse Bypass System with XL4 Controller, published on 20 Feb 2026. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2026-24790 in the wild and no public exploit code.\n\nAffected product: Welker OdorEyes EcoSystem Pulse Bypass System with XL4 Controller. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-24790/ (Markdown: https://insights.sbomify.com/CVE-2026-24790/index.md)","id":"CVE-2026-24790","markdown":"https://insights.sbomify.com/CVE-2026-24790/index.md","name":"CVE-2026-24790","record":{"aliases":["GHSA-82j5-hm8j-jwhq"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["code_execution","privilege_escalation"],"network_reachable":"yes","non_default_config":false,"product_category":"OdorEyes PLC controller","requires_auth":"none","summary":"Attackers can remotely influence the underlying PLC without authentication, potentially compromising industrial control operations.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[],"cvss":{"score":8.2,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:L","version":"3.1"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"description":"The underlying PLC of the device can be remotely influenced, without proper safeguards or authentication.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Welker OdorEyes EcoSystem Pulse Bypass System with XL4 Controller Missing Authentication for Critical Function","id":"CVE-2026-24790","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2026"},"n_packages":0,"n_references":3,"next":{"headline":"Public-only tokens bypass private-resource restrictions on `/api/v1/user` self routes","id":"CVE-2026-24791"},"packages":[],"prev":{"headline":"ZLAN Information Technology ZLAN5143D Missing Authentication for Critical Function","id":"CVE-2026-24789"},"products":["OdorEyes EcoSystem Pulse Bypass System with XL4 Controller"],"published":"2026-02-20","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-02-20","vendors":["Welker"]},"summary":"Attackers can remotely influence the underlying PLC without authentication, potentially compromising industrial control operations.","url":"https://insights.sbomify.com/CVE-2026-24790/"}