{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2026-2514 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-2514 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-2514 is a high-severity cross-site scripting vulnerability in Progress Software Flowmon ADS, published on 12 Mar 2026. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2026-2514 and fix it if it is affected.\n\nWhat it is: CVE-2026-2514 is a high-severity cross-site scripting vulnerability in Progress Software Flowmon ADS, published on 12 Mar 2026. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2026-2514 in the wild and no public exploit code.\n\nAffected product: Progress Software Flowmon ADS. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-2514/ (Markdown: https://insights.sbomify.com/CVE-2026-2514/index.md)","id":"CVE-2026-2514","markdown":"https://insights.sbomify.com/CVE-2026-2514/index.md","name":"CVE-2026-2514","record":{"aliases":["GHSA-86m2-9852-4x9r"],"analysis":{"component_type":"web_application","fix_type":"upgrade","impacts":["code_execution","account_takeover"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Flowmon ADS","requires_auth":"none","summary":"An attacker can execute unintended actions in a user's browser by crafting malicious network data viewed in the Flowmon ADS web application.","user_interaction":"required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"ProgressSoftware","cpe":[{"product":"flowmon_anomaly_detection_system","vendor":"progress"}],"cvss":{"score":8.6,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:L/SI:L/SA:N","version":"4.0"},"cwes":[{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"}],"description":"In Progress Flowmon ADS versions prior to 12.5.5 and 13.0.3, a vulnerability exists whereby an adversary with access to Flowmon monitoring ports may craft malicious network data that, when processed by Flowmon ADS and viewed by an authenticated user, could result in unintended actions being executed in the user's browser context.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Possibility of unintended actions when viewing maliciously crafted network data in Progress Flowmon ADS web application","id":"CVE-2026-2514","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xss","year":"2026"},"n_packages":0,"n_references":1,"next":{"headline":"Hostinger Reach \u003c= 1.3.8 - Missing Authorization to Authenticated (Subscriber+) Integration API Key Update","id":"CVE-2026-2515"},"packages":[],"prev":{"headline":"Cross-site scripting in Flowmon ADS","id":"CVE-2026-2513"},"products":["Flowmon ADS"],"published":"2026-03-12","related":[{"cvss_score":8.8,"headline":"SQL injection leading to privilege escalation in Progress Flowmon ADS","id":"CVE-2025-13774","kev_date_added":null,"published":"2026-01-13"},{"cvss_score":8.7,"headline":"Possibility of unintended database operations when querying data related to detected anomalies in Progress Flowmon ADS","id":"CVE-2026-9272","kev_date_added":null,"published":"2026-07-02"},{"cvss_score":8.6,"headline":"Cross-site scripting in Flowmon ADS","id":"CVE-2026-2513","kev_date_added":null,"published":"2026-03-12"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-03-13","vendors":["Progress Software"]},"summary":"An attacker can execute unintended actions in a user's browser by crafting malicious network data viewed in the Flowmon ADS web application.","url":"https://insights.sbomify.com/CVE-2026-2514/"}