{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2026-25599 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-25599 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-25599 is a medium-severity cross-site scripting vulnerability in Orca heat pump, published on 1 Jun 2026. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2026-25599 and fix it if it is affected.\n\nWhat it is: CVE-2026-25599 is a medium-severity cross-site scripting vulnerability in Orca heat pump, published on 1 Jun 2026. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2026-25599 in the wild and no public exploit code.\n\nAffected product: Orca heat pump. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-25599/ (Markdown: https://insights.sbomify.com/CVE-2026-25599/index.md)","id":"CVE-2026-25599","markdown":"https://insights.sbomify.com/CVE-2026-25599/index.md","name":"CVE-2026-25599","record":{"aliases":["GHSA-m272-v6vr-r4ff"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["account_takeover","data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Orca heat pump","requires_auth":"none","summary":"Attackers can inject malicious code into the Orca user portal via unauthenticated heat pump devices, leading to cookie theft and account compromise.","user_interaction":"required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"ENISA","cpe":[],"cvss":{"score":6.3,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L","version":"3.1"},"cwes":[{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"},{"id":"CWE-319","name":"Cleartext Transmission of Sensitive Information"},{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"description":"Missing authentication and clear‑text transmission of data from the heat pumps to the control server, combined with the absence of input validation on aggregated data, can lead to stored XSS that enables theft of cookies from the pump’s web control interface. Older Orca heat pump devices communicating with the Orca server over an \nunencrypted and unauthenticated HTTP connection on a non-secure port specifically enable an\n attacker to impersonate a legitimate device and inject malicious \npayloads. This enables the insertion of harmful code directly\n into the Orca user portal, potentially compromising user accounts, \nexposing sensitive information, and allowing further unauthorized \nactions within the portal.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Missing authentication and clear‑text data transmission affecting Orca heat pumps","id":"CVE-2026-25599","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xss","year":"2026"},"n_packages":0,"n_references":1,"next":{"headline":"Credential Exposure Vulnerability in Trac PDBM","id":"CVE-2026-25600"},"packages":[],"prev":{"headline":"Bypassing Logging of Outbound Connections Using sendto, sendmsg, and sendmmsg in Harden-Runner (Community Tier)","id":"CVE-2026-25598"},"products":["Orca heat pump","Orca user portal"],"published":"2026-06-01","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-06-01","vendors":["Orca Energy"]},"summary":"Attackers can inject malicious code into the Orca user portal via unauthenticated heat pump devices, leading to cookie theft and account compromise.","url":"https://insights.sbomify.com/CVE-2026-25599/"}