CVE-2026-25786 Cross-site scripting in SIMATIC Drive Controller CPU 1504D TF

Critical 9.3 Published Updated

An authenticated attacker can inject malicious scripts into the web interface, leading to code execution in the victim's session.

Exploited in the wild
Not known
Login needed
An administrator
Attackable
Over the internet
Victim action needed
A user has to click or open something
Fix
None listed

What is CVE-2026-25786?

CVE-2026-25786 is a critical cross-site scripting vulnerability in Siemens SIMATIC Drive Controller CPU 1504D TF, published on 12 May 2026. An attacker needs administrator access to exploit it, and only if a user opens a file or follows a link.

Official description

Affected devices do not properly validate and sanitize PLC/station name rendered on the "communication" parameters page of the web interface. This could allow an authenticated attacker who is authorized to download a TIA project into the product, to inject malicious scripts into the page. If a benign user with appropriate rights accesses the "communication" parameters page, the malicious code would be executed in the scope of their web session.

Weakness: CWE-79

Which versions are affected by CVE-2026-25786?

How do I fix CVE-2026-25786?

No fix has been published for CVE-2026-25786 yet. Limit exposure of the affected software until one is available.

Escape output for the context it lands in and set a strict Content Security Policy. Upgrading the affected component is the real fix. More about Cross-site scripting.

Is CVE-2026-25786 being exploited?

There is no known exploitation of CVE-2026-25786 in the wild and no public exploit code.

Sources

Also known as GHSA-mg8g-5fc8-4fqp.

Is CVE-2026-25786 in your software?

Upload an SBOM and sbomify checks it against every vulnerability here, every day.

Check your SBOMs for free