{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2026-27668 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-27668 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-27668 is a high-severity vulnerability in Siemens RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P), published on 14 Apr 2026."},"fix_prompt":"Check this codebase for CVE-2026-27668 and fix it if it is affected.\n\nWhat it is: CVE-2026-27668 is a high-severity vulnerability in Siemens RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P), published on 14 Apr 2026. \nExploitation: There is no known exploitation of CVE-2026-27668 in the wild and no public exploit code.\n\nAffected product: Siemens RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-27668/ (Markdown: https://insights.sbomify.com/CVE-2026-27668/index.md)","id":"CVE-2026-27668","markdown":"https://insights.sbomify.com/CVE-2026-27668/index.md","name":"CVE-2026-27668","record":{"aliases":["GHSA-r593-vh4q-g7mv"],"analysis":null,"analysis_generated_by":null,"assigner":"siemens","cpe":[],"cvss":{"score":8.7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-266","name":"Incorrect Privilege Assignment"}],"description":"A vulnerability has been identified in RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P) (All versions \u003c V5.8). User Administrators are allowed to administer groups they belong to. This could allow an authenticated User Administrator to escalate their own privileges and grant themselves access to any device group at any access level.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"A vulnerability has been identified in RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P) (All versions \u003c V5.8).","id":"CVE-2026-27668","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":null,"year":"2026"},"n_packages":0,"n_references":1,"next":{"headline":"OpenClaw \u003c 2026.3.2 - Arbitrary File Write via ZIP Extraction Parent Symlink Race Condition","id":"CVE-2026-27670"},"packages":[],"prev":{"headline":"Memory corruption in CPCI85 Central Processing/Communication","id":"CVE-2026-27664"},"products":["RUGGEDCOM CROSSBOW Secure Access Manager Primary (SAM-P)"],"published":"2026-04-14","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-04-14","vendors":["Siemens"]},"summary":null,"url":"https://insights.sbomify.com/CVE-2026-27668/"}