{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2026-27752 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-27752 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-27752 is a high-severity vulnerability in Shenzhen Hongyavision Technology Co., Ltd. (Sodola Networks) SODOLA SL902-SWTGW124AS, published on 27 Feb 2026. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-27752 and fix it if it is affected.\n\nWhat it is: CVE-2026-27752 is a high-severity vulnerability in Shenzhen Hongyavision Technology Co., Ltd. (Sodola Networks) SODOLA SL902-SWTGW124AS, published on 27 Feb 2026. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2026-27752 in the wild and no public exploit code.\n\nAffected product: Shenzhen Hongyavision Technology Co., Ltd. (Sodola Networks) SODOLA SL902-SWTGW124AS. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-27752/ (Markdown: https://insights.sbomify.com/CVE-2026-27752/index.md)","id":"CVE-2026-27752","markdown":"https://insights.sbomify.com/CVE-2026-27752/index.md","name":"CVE-2026-27752","record":{"aliases":["GHSA-xp4w-rp7m-jgwq"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["data_read","account_takeover"],"network_reachable":"yes","non_default_config":false,"product_category":"SODOLA network gateway","requires_auth":"none","summary":"Attackers can intercept cleartext credentials transmitted over HTTP to gain administrative access to the SODOLA network gateway.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulnCheck","cpe":[{"product":"sl902-swtgw124as_firmware","vendor":"sodola-network"}],"cvss":{"score":8.2,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-319","name":"Cleartext Transmission of Sensitive Information"}],"description":"SODOLA SL902-SWTGW124AS firmware versions through 200.1.20 transmit authentication credentials over unencrypted HTTP, allowing attackers to capture credentials. An attacker positioned to observe network traffic between a user and the device can intercept credentials and reuse them to gain administrative access to the gateway.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"SODOLA SL902-SWTGW124AS \u003c= 200.1.20 Cleartext Credential Transmission","id":"CVE-2026-27752","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2026"},"n_packages":0,"n_references":2,"next":{"headline":"SODOLA SL902-SWTGW124AS \u003c= 200.1.20 Improper Login Rate Limiting","id":"CVE-2026-27753"},"packages":[],"prev":{"headline":"SODOLA SL902-SWTGW124AS \u003c= 200.1.20 Use of Default Credentials","id":"CVE-2026-27751"},"products":["SODOLA SL902-SWTGW124AS"],"published":"2026-02-27","related":[{"cvss_score":9.3,"headline":"SODOLA SL902-SWTGW124AS \u003c= 200.1.20 Use of Default Credentials","id":"CVE-2026-27751","kev_date_added":null,"published":"2026-02-27"},{"cvss_score":9.3,"headline":"SODOLA SL902-SWTGW124AS \u003c= 200.1.20 Predictable Session ID","id":"CVE-2026-27755","kev_date_added":null,"published":"2026-02-27"},{"cvss_score":7.1,"headline":"SODOLA SL902-SWTGW124AS \u003c= 200.1.20 Unverified Password Change","id":"CVE-2026-27757","kev_date_added":null,"published":"2026-02-27"},{"cvss_score":6.9,"headline":"SODOLA SL902-SWTGW124AS \u003c= 200.1.20 Improper Login Rate Limiting","id":"CVE-2026-27753","kev_date_added":null,"published":"2026-02-27"},{"cvss_score":6.9,"headline":"SODOLA SL902-SWTGW124AS \u003c= 200.1.20 MD5 Session Token Generation","id":"CVE-2026-27754","kev_date_added":null,"published":"2026-02-27"},{"cvss_score":5.1,"headline":"SODOLA SL902-SWTGW124AS \u003c= 200.1.20 Reflected XSS in Management Interface","id":"CVE-2026-27756","kev_date_added":null,"published":"2026-02-27"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-03-02","vendors":["Shenzhen Hongyavision Technology Co., Ltd. (Sodola Networks)"]},"summary":"Attackers can intercept cleartext credentials transmitted over HTTP to gain administrative access to the SODOLA network gateway.","url":"https://insights.sbomify.com/CVE-2026-27752/"}