{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2026-28760 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-28760 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-28760 is a high-severity vulnerability in RATOC RAID Monitoring Manager for Windows, published on 26 Mar 2026. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2026-28760 and fix it if it is affected.\n\nWhat it is: CVE-2026-28760 is a high-severity vulnerability in RATOC RAID Monitoring Manager for Windows, published on 26 Mar 2026. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2026-28760 in the wild and no public exploit code.\n\nAffected product: RATOC RAID Monitoring Manager for Windows. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-28760/ (Markdown: https://insights.sbomify.com/CVE-2026-28760/index.md)","id":"CVE-2026-28760","markdown":"https://insights.sbomify.com/CVE-2026-28760/index.md","name":"CVE-2026-28760","record":{"aliases":["GHSA-c8rm-hg85-p336"],"analysis":{"component_type":"desktop_application","fix_type":"patch","impacts":["code_execution","privilege_escalation"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"RAID monitoring software","requires_auth":"none","summary":"Attackers can execute arbitrary code with administrator privileges by placing a malicious DLL in the installer's directory.","user_interaction":"required","vuln_class":"other"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"jpcert","cpe":[],"cvss":{"score":8.4,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-427","name":"Uncontrolled Search Path Element"}],"description":"The installer of RATOC RAID Monitoring Manager for Windows searches the current directory to load certain DLLs. If a user is directed to place a crafted DLL with the installer, an arbitrary code may be executed with the administrator privilege.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Other in RATOC RAID Monitoring Manager for Windows","id":"CVE-2026-28760","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"other","year":"2026"},"n_packages":0,"n_references":2,"next":{"headline":"Cross-site request forgery in Musetheque V4 Information Disclosure for IPKNOWLEDGE","id":"CVE-2026-28761"},"packages":[],"prev":{"headline":"Mattermost does not verify remote cluster channel access when processing shared channel membership removals","id":"CVE-2026-28759"},"products":["RATOC RAID Monitoring Manager for Windows"],"published":"2026-03-26","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-03-26","vendors":["RATOC Systems, Inc."]},"summary":"Attackers can execute arbitrary code with administrator privileges by placing a malicious DLL in the installer's directory.","url":"https://insights.sbomify.com/CVE-2026-28760/"}