{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2026-29123 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-29123 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-29123 is a high-severity vulnerability in International Datacasting Corporation SFX2100 Satellite Receiver, published on 5 Mar 2026. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-29123 and fix it if it is affected.\n\nWhat it is: CVE-2026-29123 is a high-severity vulnerability in International Datacasting Corporation SFX2100 Satellite Receiver, published on 5 Mar 2026. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2026-29123 in the wild and no public exploit code.\n\nAffected product: International Datacasting Corporation SFX2100 Satellite Receiver. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-29123/ (Markdown: https://insights.sbomify.com/CVE-2026-29123/index.md)","id":"CVE-2026-29123","markdown":"https://insights.sbomify.com/CVE-2026-29123/index.md","name":"CVE-2026-29123","record":{"aliases":["GHSA-4753-7q6g-548g"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["privilege_escalation"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Satellite Receiver","requires_auth":"low_privilege","summary":"Local attackers can escalate privileges to root by exploiting SUID binaries in the user home directory via PATH hijacking or symlink abuse.","user_interaction":"not_required","vuln_class":"privilege_escalation"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Gridware","cpe":[{"product":"sfx2100_firmware","vendor":"datacast"}],"cvss":{"score":8.6,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N","version":"4.0"},"cwes":[{"id":"CWE-269","name":"Improper Privilege Management"}],"description":"A SUID root-owned binary in /home/xd/terminal/XDTerminal in International Data Casting (IDC) SFX2100 on Linux allows a local actor to potentially preform local privilege escalation depending on conditions of the system via execution of the affected SUID binary. This can be via PATH hijacking, symlink abuse or shared object hijacking.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Multiple SUID Root Binaries in `xd` User Home Directory Leading to Potential Local Privilege Escalation","id":"CVE-2026-29123","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"privilege_escalation","year":"2026"},"n_packages":0,"n_references":1,"next":{"headline":"Multiple SUID Root Binaries in `monitor` User Home Directory Leading to Potential Local Privilege Escalation","id":"CVE-2026-29124"},"packages":[],"prev":{"headline":"`/bin/date` Binary given SETUID Permissions on IDC SFX2100 Leading to Potential LPE","id":"CVE-2026-29122"},"products":["SFX2100 Satellite Receiver"],"published":"2026-03-05","related":[{"cvss_score":10,"headline":"Unauthenticated RCE via SNMP Default Writable Community String","id":"CVE-2026-28775","kev_date_added":null,"published":"2026-03-04"},{"cvss_score":9.3,"headline":"Authenticated OS Command Injection via Ping Utility Leading to RCE as Root","id":"CVE-2026-28773","kev_date_added":null,"published":"2026-03-04"},{"cvss_score":9.3,"headline":"Authenticated OS Command Injection via Traceroute Utility leads to Root RCE","id":"CVE-2026-28774","kev_date_added":null,"published":"2026-03-04"},{"cvss_score":9.2,"headline":"Incorrect Permission Assignment(777) on `monitor` Users Home Directory Containing SUID Root Binaries in IDC SFX2100","id":"CVE-2026-29127","kev_date_added":null,"published":"2026-03-05"},{"cvss_score":9.2,"headline":"Hardcoded and Insecure Credentials for \"User\" Local Account with SSH Access On IDC SFX2100 Satellite Receiver","id":"CVE-2026-28777","kev_date_added":null,"published":"2026-03-04"},{"cvss_score":9.2,"headline":"Insecure, Hardcoded Root Password Stored in Anaconda Configuration File On IDC SFX2100 Satellite Receiver","id":"CVE-2026-29120","kev_date_added":null,"published":"2026-03-04"},{"cvss_score":8.8,"headline":"Hardcoded and Insecure Credentials for \"Admin\" Account providing Telnet Access on IDC SFX2100 Satellite Receiver","id":"CVE-2026-29119","kev_date_added":null,"published":"2026-03-04"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-03-05","vendors":["International Datacasting Corporation"]},"summary":"Local attackers can escalate privileges to root by exploiting SUID binaries in the user home directory via PATH hijacking or symlink abuse.","url":"https://insights.sbomify.com/CVE-2026-29123/"}