{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2026-33892 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-33892 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-33892 is a medium-severity authentication bypass vulnerability in Siemens Industrial Edge Management Pro V1, published on 14 Apr 2026. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2026-33892 and fix it if it is affected.\n\nWhat it is: CVE-2026-33892 is a medium-severity authentication bypass vulnerability in Siemens Industrial Edge Management Pro V1, published on 14 Apr 2026. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2026-33892 in the wild and no public exploit code.\n\nAffected product: Siemens Industrial Edge Management Pro V1. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-33892/ (Markdown: https://insights.sbomify.com/CVE-2026-33892/index.md)","id":"CVE-2026-33892","markdown":"https://insights.sbomify.com/CVE-2026-33892/index.md","name":"CVE-2026-33892","record":{"aliases":["GHSA-24c7-prh7-m3g7"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["security_bypass","privilege_escalation"],"network_reachable":"yes","non_default_config":true,"product_category":"Industrial Edge Management","requires_auth":"none","summary":"Unauthenticated remote attackers can bypass authentication to impersonate users and tunnel to devices if remote connections are enabled.","user_interaction":"required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[],"cvss":{"score":5.1,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:L/VA:N/SC:L/SI:L/SA:L","version":"4.0"},"cwes":[{"id":"CWE-305","name":"Authentication Bypass by Primary Weakness"}],"description":"A vulnerability has been identified in Industrial Edge Management Pro V1 (All versions \u003e= V1.7.6 \u003c V1.15.17), Industrial Edge Management Pro V2 (All versions \u003e= V2.0.0 \u003c V2.1.1), Industrial Edge Management Virtual (All versions \u003e= V2.2.0 \u003c V2.8.0). Affected management systems do not properly enforce user authentication on remote connections to devices.\r\nThis could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user.\r\nSuccessful exploitation requires that the attacker has identified the header and port used for remote connections to devices and that the remote connection feature is enabled for the device.\r\n\r\nExploitation allows the attacker to tunnel to the device. Security features on this device itself (e.g. app specific authentication) are not affected.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Auth bypass in Industrial Edge Management Pro V1","id":"CVE-2026-33892","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2026"},"n_packages":0,"n_references":1,"next":{"headline":"Hardcoded credentials in Teamcenter V2312","id":"CVE-2026-33893"},"packages":[],"prev":{"headline":"Forge has Denial of Service via Infinite Loop in BigInteger.modInverse() with Zero Input","id":"CVE-2026-33891"},"products":["Industrial Edge Management Pro V1","Industrial Edge Management Pro V2","Industrial Edge Management Virtual"],"published":"2026-04-14","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-04-14","vendors":["Siemens"]},"summary":"Unauthenticated remote attackers can bypass authentication to impersonate users and tunnel to devices if remote connections are enabled.","url":"https://insights.sbomify.com/CVE-2026-33892/"}