{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2026-42933 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-42933 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-42933 is a critical server-side request forgery vulnerability in Pronetiqs Panduit Intravue, published on 23 Jul 2026. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-42933 and fix it if it is affected.\n\nWhat it is: CVE-2026-42933 is a critical server-side request forgery vulnerability in Pronetiqs Panduit Intravue, published on 23 Jul 2026. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2026-42933 in the wild and no public exploit code.\n\nAffected product: Pronetiqs Panduit Intravue. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-42933/ (Markdown: https://insights.sbomify.com/CVE-2026-42933/index.md)","id":"CVE-2026-42933","markdown":"https://insights.sbomify.com/CVE-2026-42933/index.md","name":"CVE-2026-42933","record":{"aliases":["GHSA-jp3p-8p4m-hxwj"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"OT monitoring software","requires_auth":"none","summary":"An attacker can exploit an unintended proxy to bypass OT network segmentation in Pronetiqs IntraVUE, compromising industrial control system security.","user_interaction":"not_required","vuln_class":"ssrf"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[],"cvss":{"score":10,"severity":"critical","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","version":"4.0"},"cwes":[{"id":"CWE-441","name":"Unintended Proxy or Intermediary"}],"description":"Pronetiqs IntraVUE versions 3.2.1a14 and prior have an unintended proxy or intermediary vulnerability which could allow an attacker to use an active proxy, which would bypass OT segmentation.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Unintended Proxy or Intermediary in Panduit IntraVUE by Pronetiqs","id":"CVE-2026-42933","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"ssrf","year":"2026"},"n_packages":0,"n_references":1,"next":{"headline":"NGINX ngx_http_charset_module vulnerability","id":"CVE-2026-42934"},"packages":[],"prev":{"headline":"Naxclow IoT Platform Generation of Predictable Numbers or Identifiers","id":"CVE-2026-42932"},"products":["Panduit Intravue"],"published":"2026-07-23","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-07-24","vendors":["Pronetiqs"]},"summary":"An attacker can exploit an unintended proxy to bypass OT network segmentation in Pronetiqs IntraVUE, compromising industrial control system security.","url":"https://insights.sbomify.com/CVE-2026-42933/"}