{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2026-44412 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-44412 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-44412 is a high-severity memory corruption vulnerability in Siemens Solid Edge SE2026, published on 12 May 2026. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2026-44412 and fix it if it is affected.\n\nWhat it is: CVE-2026-44412 is a high-severity memory corruption vulnerability in Siemens Solid Edge SE2026, published on 12 May 2026. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2026-44412 in the wild and no public exploit code.\n\nAffected product: Siemens Solid Edge SE2026. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-44412/ (Markdown: https://insights.sbomify.com/CVE-2026-44412/index.md)","id":"CVE-2026-44412","markdown":"https://insights.sbomify.com/CVE-2026-44412/index.md","name":"CVE-2026-44412","record":{"aliases":["GHSA-38hh-m295-69vh"],"analysis":{"component_type":"desktop_application","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"CAD software","requires_auth":"none","summary":"A stack-based buffer overflow in Solid Edge allows attackers to execute arbitrary code via specially crafted PAR files.","user_interaction":"required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[],"cvss":{"score":7.3,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-121","name":"Stack-based Buffer Overflow"}],"description":"A vulnerability has been identified in Solid Edge SE2026 (All versions \u003c V226.0 Update 5). The affected applications contain a stack based overflow vulnerability while parsing specially crafted PAR files.\r\nThis could allow an attacker to execute code in the context of the current process.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Memory corruption in Solid Edge SE2026","id":"CVE-2026-44412","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2026"},"n_packages":0,"n_references":1,"next":{"headline":"Missing authorization in TeamCity","id":"CVE-2026-44413"},"packages":[],"prev":{"headline":"Memory corruption in Solid Edge SE2026","id":"CVE-2026-44411"},"products":["Solid Edge SE2026"],"published":"2026-05-12","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-05-13","vendors":["Siemens"]},"summary":"A stack-based buffer overflow in Solid Edge allows attackers to execute arbitrary code via specially crafted PAR files.","url":"https://insights.sbomify.com/CVE-2026-44412/"}