{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2026-44878 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-44878 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-44878 is a high-severity path traversal vulnerability in Hewlett Packard Enterprise (HPE) EdgeConnect SD-WAN Gateway (ECOS), published on 21 Jul 2026. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-44878 and fix it if it is affected.\n\nWhat it is: CVE-2026-44878 is a high-severity path traversal vulnerability in Hewlett Packard Enterprise (HPE) EdgeConnect SD-WAN Gateway (ECOS), published on 21 Jul 2026. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2026-44878 in the wild and no public exploit code.\n\nAffected product: Hewlett Packard Enterprise (HPE) EdgeConnect SD-WAN Gateway (ECOS). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-44878/ (Markdown: https://insights.sbomify.com/CVE-2026-44878/index.md)","id":"CVE-2026-44878","markdown":"https://insights.sbomify.com/CVE-2026-44878/index.md","name":"CVE-2026-44878","record":{"aliases":["GHSA-4qh6-m8h4-cff3"],"analysis":{"component_type":"network_device","fix_type":"patch","impacts":["data_read","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"SD-WAN Gateway","requires_auth":"high_privilege","summary":"Authenticated attackers can exploit path traversal in the web interface to read sensitive files and modify system data on HPE EdgeConnect SD-WAN Gateways.","user_interaction":"not_required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"hpe","cpe":[],"cvss":{"score":7.2,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-732","name":"Incorrect Permission Assignment for Critical Resource"},{"id":"CWE-377","name":"DEPRECATED: Insecure Temporary File"}],"description":"A vulnerability in the web-based management interface of an ECOS device could allow a highly privileged, authenticated remote attacker to access the device's filesystem. Successful exploitation of this vulnerability could allow an attacker to access sensitive files and tamper with or delete system data.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Authenticated Path Traversal allows Unauthorized Access in Web Interface","id":"CVE-2026-44878","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2026"},"n_packages":0,"n_references":1,"next":{"headline":"Authenticated Command Injection allows arbitrary command execution in CLI Interface","id":"CVE-2026-44879"},"packages":[],"prev":{"headline":"Unauthenticated Remote Disclosure of Cryptographic Secrets","id":"CVE-2026-44877"},"products":["EdgeConnect SD-WAN Gateway (ECOS)"],"published":"2026-07-21","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-07-23","vendors":["Hewlett Packard Enterprise (HPE)"]},"summary":"Authenticated attackers can exploit path traversal in the web interface to read sensitive files and modify system data on HPE EdgeConnect SD-WAN Gateways.","url":"https://insights.sbomify.com/CVE-2026-44878/"}