{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2026-49502 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-49502 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-49502 is a high-severity authentication bypass vulnerability in Dell PowerFlex, published on 17 Jun 2026. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-49502 and fix it if it is affected.\n\nWhat it is: CVE-2026-49502 is a high-severity authentication bypass vulnerability in Dell PowerFlex, published on 17 Jun 2026. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2026-49502 in the wild and no public exploit code.\n\nAffected product: Dell PowerFlex. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-49502/ (Markdown: https://insights.sbomify.com/CVE-2026-49502/index.md)","id":"CVE-2026-49502","markdown":"https://insights.sbomify.com/CVE-2026-49502/index.md","name":"CVE-2026-49502","record":{"aliases":["GHSA-jw62-xc2q-92gm"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["data_read","data_modify","security_bypass"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Dell PowerFlex Manager","requires_auth":"none","summary":"An unauthenticated attacker with adjacent network access can bypass authentication in Dell PowerFlex Manager to disclose and tamper with information.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"dell","cpe":[{"product":"powerflex_manager","vendor":"dell"}],"cvss":{"score":7.4,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-287","name":"Improper Authentication"}],"description":"Dell PowerFlex Manager, version(s) prior to 5.1.0.1, contain(s) an Improper Authentication vulnerability. An unauthenticated attacker with adjacent network access could potentially exploit this vulnerability, leading to Information disclosure, Information tampering, and Unauthorized access.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Auth bypass in PowerFlex","id":"CVE-2026-49502","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2026"},"n_packages":0,"n_references":1,"next":{"headline":"Path traversal in Wyse Management Suite","id":"CVE-2026-49506"},"packages":[],"prev":{"headline":"Privilege escalation in PowerScale OneFS","id":"CVE-2026-49501"},"products":["PowerFlex"],"published":"2026-06-17","related":[{"cvss_score":9.1,"headline":"Command injection in PowerFlex Manager","id":"CVE-2026-56688","kev_date_added":null,"published":"2026-07-10"},{"cvss_score":8.8,"headline":"Missing authorization in PowerFlex","id":"CVE-2026-35065","kev_date_added":null,"published":"2026-06-17"},{"cvss_score":8.5,"headline":"SQL injection in PowerFlex Manager","id":"CVE-2026-56690","kev_date_added":null,"published":"2026-07-10"},{"cvss_score":8.1,"headline":"Auth bypass in PowerFlex","id":"CVE-2026-32804","kev_date_added":null,"published":"2026-06-17"},{"cvss_score":7.7,"headline":"SQL injection in PowerFlex Manager","id":"CVE-2026-56689","kev_date_added":null,"published":"2026-07-10"},{"cvss_score":7.5,"headline":"Information disclosure in PowerFlex","id":"CVE-2026-22283","kev_date_added":null,"published":"2026-06-17"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-06-25","vendors":["Dell"]},"summary":"An unauthenticated attacker with adjacent network access can bypass authentication in Dell PowerFlex Manager to disclose and tamper with information.","url":"https://insights.sbomify.com/CVE-2026-49502/"}