{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2026-49815 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-49815 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-49815 is a high-severity command injection vulnerability in Dell Data Domain Operating System, published on 3 Jul 2026. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-49815 and fix it if it is affected.\n\nWhat it is: CVE-2026-49815 is a high-severity command injection vulnerability in Dell Data Domain Operating System, published on 3 Jul 2026. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2026-49815 in the wild and no public exploit code.\n\nAffected product: Dell Data Domain Operating System. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-49815/ (Markdown: https://insights.sbomify.com/CVE-2026-49815/index.md)","id":"CVE-2026-49815","markdown":"https://insights.sbomify.com/CVE-2026-49815/index.md","name":"CVE-2026-49815","record":{"aliases":["GHSA-363q-xrjc-rqpj"],"analysis":{"component_type":"server_software","fix_type":"patch","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Data Domain backup system","requires_auth":"high_privilege","summary":"A high-privileged remote attacker can execute arbitrary OS commands on Dell PowerProtect Data Domain systems via an OS command injection vulnerability.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"dell","cpe":[{"product":"data_domain_operating_system","vendor":"dell"}],"cvss":{"score":7.2,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"}],"description":"Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 contain an improper neutralization of special Elements used in an OS command ('OS command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to execution of arbitrary OS commands.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Command injection in PowerProtect Data Domain","id":"CVE-2026-49815","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"dell:data_domain_operating_system","products":["dell:data_domain_operating_system"],"type":"command_injection","year":"2026"},"n_packages":0,"n_references":1,"next":{"headline":"Deserialization in Dell Command Update (DCU)","id":"CVE-2026-49816"},"packages":[],"prev":{"headline":"Command injection in PowerProtect Data Domain","id":"CVE-2026-49814"},"products":["PowerProtect Data Domain"],"published":"2026-07-03","related":[{"cvss_score":9.8,"headline":"Path traversal in PowerProtect Data Domain","id":"CVE-2026-53481","kev_date_added":null,"published":"2026-07-07"},{"cvss_score":9.8,"headline":"Auth bypass in PowerProtect Data Domain","id":"CVE-2026-53483","kev_date_added":null,"published":"2026-07-07"},{"cvss_score":9.8,"headline":"Auth bypass in PowerProtect Data Domain Feature Release","id":"CVE-2025-36594","kev_date_added":null,"published":"2025-08-04"},{"cvss_score":8.8,"headline":"Missing authorization in PowerProtect Data Domain","id":"CVE-2026-56086","kev_date_added":null,"published":"2026-07-08"},{"cvss_score":8.8,"headline":"Missing authorization in PowerProtect Data Domain","id":"CVE-2026-26944","kev_date_added":null,"published":"2026-04-20"},{"cvss_score":8.8,"headline":"Privilege escalation in DD OS 7.10","id":"CVE-2025-29987","kev_date_added":null,"published":"2025-04-03"},{"cvss_score":8.8,"headline":"Memory corruption in PowerProtect DD","id":"CVE-2024-29176","kev_date_added":null,"published":"2024-06-26"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-07-07","vendors":["Dell"]},"summary":"A high-privileged remote attacker can execute arbitrary OS commands on Dell PowerProtect Data Domain systems via an OS command injection vulnerability.","url":"https://insights.sbomify.com/CVE-2026-49815/"}