CVE-2026-5156 Tenda CH22 Parameter QuickIndex formQuickIndex stack-based overflow

High 8.7 Published Updated

Remote attackers can trigger a stack-based buffer overflow in the Tenda CH22 router via the QuickIndex parameter, potentially leading to code execution.

Exploited in the wild
Not known
Login needed
Any signed-in user
Attackable
Over the internet
Victim action needed
Not needed
Fix
None listed

What is CVE-2026-5156?

CVE-2026-5156 is a high-severity memory corruption vulnerability in Tenda CH22, published on 30 Mar 2026. Any signed-in user can exploit it over the network, with no action from the victim.

Official description

A vulnerability was determined in Tenda CH22 1.0.0.1. This impacts the function formQuickIndex of the file /goform/QuickIndex of the component Parameter Handler. This manipulation of the argument mit_linktype causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized.

Weakness: CWE-121, CWE-787, CWE-119

Which versions are affected by CVE-2026-5156?

It affects 1 product.

Products include Tenda Ch22 Firmware.

How do I fix CVE-2026-5156?

No fix has been published for CVE-2026-5156 yet. Limit exposure of the affected software until one is available.

Upgrade to the fixed version. Memory-safe languages, compiler hardening and fuzzing prevent most new cases. More about Memory corruption.

Is CVE-2026-5156 being exploited?

It is not confirmed as exploited in the wild, but public exploit code for CVE-2026-5156 exists.

Sources

Also known as GHSA-q7wf-8q63-47pq.

Is CVE-2026-5156 in your software?

Upload an SBOM and sbomify checks it against every vulnerability here, every day.

Check your SBOMs for free