{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2026-5184 exists.","fix":"No fix has been published for CVE-2026-5184 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-5184 is a medium-severity command injection vulnerability in TRENDnet TEW-713RE, published on 31 Mar 2026. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-5184 and fix it if it is affected.\n\nWhat it is: CVE-2026-5184 is a medium-severity command injection vulnerability in TRENDnet TEW-713RE, published on 31 Mar 2026. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2026-5184 exists.\n\nAffected product: TRENDnet TEW-713RE. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-5184/ (Markdown: https://insights.sbomify.com/CVE-2026-5184/index.md)","id":"CVE-2026-5184","markdown":"https://insights.sbomify.com/CVE-2026-5184/index.md","name":"CVE-2026-5184","record":{"aliases":["GHSA-wv84-v8gw-jhh5"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"TRENDnet range extender","requires_auth":"low_privilege","summary":"Remote attackers can execute arbitrary commands via the admuser argument in the setSysAdm interface of TRENDnet TEW-713RE devices.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"tew-713re_firmware","vendor":"trendnet"}],"cvss":{"score":5.3,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P","version":"4.0"},"cwes":[{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"},{"id":"CWE-74","name":"Improper Neutralization of Special Elements in Output Used by a Downstream Component"}],"description":"A vulnerability was identified in TRENDnet TEW-713RE up to 1.02. The impacted element is an unknown function of the file /goform/setSysAdm. The manipulation of the argument admuser leads to command injection. The attack can be initiated remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"TRENDnet TEW-713RE setSysAdm command injection","id":"CVE-2026-5184","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2026"},"n_packages":0,"n_references":4,"next":{"headline":"Nothings stb_image Multi-frame GIF File stb_image.h stbi__gif_load_next heap-based overflow","id":"CVE-2026-5185"},"packages":[],"prev":{"headline":"TRENDnet TEW-713RE addRouting sub_421494 command injection","id":"CVE-2026-5183"},"products":["TEW-713RE"],"published":"2026-03-31","related":[{"cvss_score":9.3,"headline":"TRENDnet TEW-713RE formFSrvX os command injection","id":"CVE-2025-15471","kev_date_added":null,"published":"2026-01-06"},{"cvss_score":5.3,"headline":"TRENDnet TEW-713RE addRouting sub_421494 command injection","id":"CVE-2026-5183","kev_date_added":null,"published":"2026-03-31"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-03-31","vendors":["TRENDnet"]},"summary":"Remote attackers can execute arbitrary commands via the admuser argument in the setSysAdm interface of TRENDnet TEW-713RE devices.","url":"https://insights.sbomify.com/CVE-2026-5184/"}