{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2026-5302 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-5302 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-5302 is a medium-severity vulnerability in coolercontrold, published on 8 Apr 2026. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2026-5302 and fix it if it is affected.\n\nWhat it is: CVE-2026-5302 is a medium-severity vulnerability in coolercontrold, published on 8 Apr 2026. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2026-5302 in the wild and no public exploit code.\n\nAffected product: coolercontrold. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-5302/ (Markdown: https://insights.sbomify.com/CVE-2026-5302/index.md)","id":"CVE-2026-5302","markdown":"https://insights.sbomify.com/CVE-2026-5302/index.md","name":"CVE-2026-5302","record":{"aliases":["GHSA-vhqm-xjcf-g4x8"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["data_read","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"CoolerControl daemon","requires_auth":"none","summary":"Attackers can read data and send commands to CoolerControl via malicious websites due to permissive CORS settings.","user_interaction":"required","vuln_class":"misconfiguration"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"GitLab","cpe":[{"product":"coolercontrold","vendor":"coolercontrol"}],"cvss":{"score":6.3,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L","version":"3.1"},"cwes":[{"id":"CWE-942","name":"Permissive Cross-domain Security Policy with Untrusted Domains"}],"description":"CORS misconfiguration in CoolerControl/coolercontrold \u003c4.0.0 allows unauthenticated remote attackers to read data and send commands to the service via malicious websites","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":false,"headline":"Permissive Cross-domain Policy with Untrusted Domains in coolercontrold","id":"CVE-2026-5302","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"misconfiguration","year":"2026"},"n_packages":0,"n_references":2,"next":{"headline":"Race condition in AXIS OS","id":"CVE-2026-5303"},"packages":[],"prev":{"headline":"Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in coolercontrol-ui","id":"CVE-2026-5301"},"products":["coolercontrold"],"published":"2026-04-08","related":[{"cvss_score":8.2,"headline":"Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in coolercontrold","id":"CVE-2026-5208","kev_date_added":null,"published":"2026-04-08"},{"cvss_score":7.6,"headline":"Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in coolercontrol-ui","id":"CVE-2026-5301","kev_date_added":null,"published":"2026-04-08"},{"cvss_score":5.9,"headline":"Missing Authentication for Critical Function in coolercontrold","id":"CVE-2026-5300","kev_date_added":null,"published":"2026-04-08"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-04-08","vendors":["CoolerControl"]},"summary":"Attackers can read data and send commands to CoolerControl via malicious websites due to permissive CORS settings.","url":"https://insights.sbomify.com/CVE-2026-5302/"}