{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2026-57263 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-57263 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-57263 is a high-severity vulnerability in Siemens LOGO! Soft Comfort, published on 11 Aug 2026. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-57263 and fix it if it is affected.\n\nWhat it is: CVE-2026-57263 is a high-severity vulnerability in Siemens LOGO! Soft Comfort, published on 11 Aug 2026. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2026-57263 in the wild and no public exploit code.\n\nAffected product: Siemens LOGO! Soft Comfort. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-57263/ (Markdown: https://insights.sbomify.com/CVE-2026-57263/index.md)","id":"CVE-2026-57263","markdown":"https://insights.sbomify.com/CVE-2026-57263/index.md","name":"CVE-2026-57263","record":{"aliases":["GHSA-pmf3-v4rm-f24p"],"analysis":{"component_type":"desktop_application","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Siemens LOGO! Soft Comfort","requires_auth":"none","summary":"Attackers can crack project passwords via offline brute-force due to unsalted SHA-256 hashing, exposing sensitive project data.","user_interaction":"not_required","vuln_class":"weak_cryptography"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[],"cvss":{"score":7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-759","name":"Use of a One-Way Hash without a Salt"}],"description":"A vulnerability has been identified in LOGO! Soft Comfort (All versions \u003c V9). The project password feature in the affected products stores the password as an unsalted SHA-256 hash. This could allow an attacker who has obtained the project file to perform efficient offline dictionary or brute-force attacks against the unsalted hash.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Weak cryptography in LOGO! Soft Comfort","id":"CVE-2026-57263","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"weak_cryptography","year":"2026"},"n_packages":0,"n_references":1,"next":{"headline":"GeoVision GeoWebPlayer Websocket Server out-of-bounds read vulnerability","id":"CVE-2026-57264"},"packages":[],"prev":{"headline":"Hardcoded credentials in LOGO! Soft Comfort","id":"CVE-2026-57262"},"products":["LOGO! Soft Comfort"],"published":"2026-08-11","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-08-11","vendors":["Siemens"]},"summary":"Attackers can crack project passwords via offline brute-force due to unsalted SHA-256 hashing, exposing sensitive project data.","url":"https://insights.sbomify.com/CVE-2026-57263/"}