{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2026-57600 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-57600 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-57600 is a high-severity vulnerability in Hikvision DS-2CD Series, published on 22 Jul 2026. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-57600 and fix it if it is affected.\n\nWhat it is: CVE-2026-57600 is a high-severity vulnerability in Hikvision DS-2CD Series, published on 22 Jul 2026. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2026-57600 in the wild and no public exploit code.\n\nAffected product: Hikvision DS-2CD Series. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-57600/ (Markdown: https://insights.sbomify.com/CVE-2026-57600/index.md)","id":"CVE-2026-57600","markdown":"https://insights.sbomify.com/CVE-2026-57600/index.md","name":"CVE-2026-57600","record":{"aliases":["GHSA-gr8g-8h3g-v65p"],"analysis":{"component_type":"iot_embedded","fix_type":"patch","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Hikvision IP camera","requires_auth":"none","summary":"Unauthenticated attackers can retrieve partial sensitive data from Hikvision cameras due to insufficient input validation in the firmware.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"hikvision","cpe":[],"cvss":{"score":7.5,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-20","name":"Improper Input Validation"}],"description":"Insufficient validation of input parameters in the firmware of some Hikvision cameras allows unauthenticated attackers to retrieve partial sensitive data.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in DS-2CD Series","id":"CVE-2026-57600","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2026"},"n_packages":0,"n_references":1,"next":{"headline":"WordPress SeedProd Pro plugin \u003c 6.19.5 - Cross Site Scripting (XSS) vulnerability","id":"CVE-2026-57617"},"packages":[],"prev":{"headline":"Privilege escalation in DS-2CD Series","id":"CVE-2026-57599"},"products":["DS-2CD Series","DS-2DE Series","DS-2DP Series","DS-2TD Series"],"published":"2026-07-22","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-07-22","vendors":["Hikvision"]},"summary":"Unauthenticated attackers can retrieve partial sensitive data from Hikvision cameras due to insufficient input validation in the firmware.","url":"https://insights.sbomify.com/CVE-2026-57600/"}