CVE-2026-58115 Missing authorization in SIMATIC IoT2050 Advanced

Critical 10.0 Published Updated

Unauthenticated remote attackers can execute arbitrary code with maximum privileges on SIMATIC IoT2050 devices via the Node-RED interface.

Exploited in the wild
Not known
Login needed
Not needed
Attackable
Over the internet
Victim action needed
Not needed
Fix
None listed

What is CVE-2026-58115?

CVE-2026-58115 is a critical missing authorization vulnerability in Siemens SIMATIC IoT2050 Advanced, published on 11 Aug 2026. An attacker can exploit it over the internet without logging in, with no action from the victim.

Official description

A vulnerability has been identified in SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions < V4.3.4.1 running Industrial OS with Node-RED installed). Affected devices do not enforce authentication on the Node-RED HTTP interface, allowing unauthenticated access to programming nodes that are capable of executing system commands on the server. This could allow an unauthenticated remote attacker to create malicious flows through the HTTP interface in order to execute arbitrary code on the underlying server with maximum privileges.

Weakness: CWE-306

Which versions are affected by CVE-2026-58115?

How do I fix CVE-2026-58115?

No fix has been published for CVE-2026-58115 yet. Limit exposure of the affected software until one is available.

Upgrade, and check permissions on every request on the server, not only in the interface. More about Missing authorization.

Is CVE-2026-58115 being exploited?

There is no known exploitation of CVE-2026-58115 in the wild and no public exploit code.

Sources

Also known as GHSA-mmh6-f99q-64fh.

Is CVE-2026-58115 in your software?

Upload an SBOM and sbomify checks it against every vulnerability here, every day.