{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2026-58115 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-58115 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-58115 is a critical missing authorization vulnerability in Siemens SIMATIC IoT2050 Advanced, published on 11 Aug 2026. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-58115 and fix it if it is affected.\n\nWhat it is: CVE-2026-58115 is a critical missing authorization vulnerability in Siemens SIMATIC IoT2050 Advanced, published on 11 Aug 2026. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2026-58115 in the wild and no public exploit code.\n\nAffected product: Siemens SIMATIC IoT2050 Advanced. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-58115/ (Markdown: https://insights.sbomify.com/CVE-2026-58115/index.md)","id":"CVE-2026-58115","markdown":"https://insights.sbomify.com/CVE-2026-58115/index.md","name":"CVE-2026-58115","record":{"aliases":["GHSA-mmh6-f99q-64fh"],"analysis":{"component_type":"iot_embedded","fix_type":"upgrade","impacts":["code_execution","privilege_escalation"],"network_reachable":"yes","non_default_config":false,"product_category":"Industrial IoT gateway","requires_auth":"none","summary":"Unauthenticated remote attackers can execute arbitrary code with maximum privileges on SIMATIC IoT2050 devices via the Node-RED interface.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[],"cvss":{"score":10,"severity":"critical","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H","version":"4.0"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"description":"A vulnerability has been identified in SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions \u003c V4.3.4.1 running Industrial OS with Node-RED installed). Affected devices do not enforce authentication on the Node-RED HTTP interface, allowing unauthenticated access to programming nodes that are capable of executing system commands on the server.\r\nThis could allow an unauthenticated remote attacker to create malicious flows through the HTTP interface in order to execute arbitrary code on the underlying server with maximum privileges.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Missing authorization in SIMATIC IoT2050 Advanced","id":"CVE-2026-58115","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2026"},"n_packages":0,"n_references":1,"next":{"headline":"LLaMA-Factory 0.9.5 Remote Code Execution via WebUI Model Path","id":"CVE-2026-58116"},"packages":[],"prev":{"headline":"Cross-site scripting in Teamcenter V2412","id":"CVE-2026-58113"},"products":["SIMATIC IoT2050 Advanced"],"published":"2026-08-11","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-08-12","vendors":["Siemens"]},"summary":"Unauthenticated remote attackers can execute arbitrary code with maximum privileges on SIMATIC IoT2050 devices via the Node-RED interface.","url":"https://insights.sbomify.com/CVE-2026-58115/"}