{"answers":{"affected":"","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2026-59720 exists.","fix":"No fix has been published for CVE-2026-59720 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-59720 is a high-severity vulnerability in hoppscotch, published on 9 Jul 2026. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-59720 and fix it if it is affected.\n\nWhat it is: CVE-2026-59720 is a high-severity vulnerability in hoppscotch, published on 9 Jul 2026. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2026-59720 exists.\n\nAffected product: hoppscotch. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-59720/ (Markdown: https://insights.sbomify.com/CVE-2026-59720/index.md)","id":"CVE-2026-59720","markdown":"https://insights.sbomify.com/CVE-2026-59720/index.md","name":"CVE-2026-59720","record":{"aliases":["GHSA-c68f-wr5p-j6jf"],"analysis":{"component_type":"web_application","fix_type":"upgrade","impacts":["data_read","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"API development tool","requires_auth":"none","summary":"Attackers can access private API collection data via mock servers due to insecure default settings exposing data without authentication.","user_interaction":"not_required","vuln_class":"misconfiguration"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"GitHub_M","cpe":[],"cvss":{"score":7.5,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-284","name":"Improper Access Control"},{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"description":"Hoppscotch is an open source API development ecosystem. Prior to 2026.6.0, mock server creation in mock-server.service.ts does not persist the isPublic input field while schema.prisma defaults isPublic to true, causing mock servers linked to private collections to be publicly accessible without authentication and potentially expose sensitive API data. This issue is fixed in version 2026.6.0.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":false,"headline":"Hoppscotch: Insecure Default Configuration Allows Public Exposure of Private Collection Data via Mock Server","id":"CVE-2026-59720","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"misconfiguration","year":"2026"},"n_packages":0,"n_references":4,"next":{"headline":"Hoppscotch: Admin RCE via MAILER_SMTP_URL nodemailer sendmail-transport injection","id":"CVE-2026-59721"},"packages":[],"prev":{"headline":"Home Assistant Companion: `homeassistant://invite` Deep Link Credential Phishing","id":"CVE-2026-59717"},"products":["hoppscotch"],"published":"2026-07-09","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"poc","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-07-09","vendors":["hoppscotch"]},"summary":"Attackers can access private API collection data via mock servers due to insecure default settings exposing data without authentication.","url":"https://insights.sbomify.com/CVE-2026-59720/"}