{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2026-62654 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-62654 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-62654 is a high-severity code injection vulnerability in Siemens Reyrolle 7SR5, published on 8 Sep 2026. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-62654 and fix it if it is affected.\n\nWhat it is: CVE-2026-62654 is a high-severity code injection vulnerability in Siemens Reyrolle 7SR5, published on 8 Sep 2026. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2026-62654 in the wild and no public exploit code.\n\nAffected product: Siemens Reyrolle 7SR5. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-62654/ (Markdown: https://insights.sbomify.com/CVE-2026-62654/index.md)","id":"CVE-2026-62654","markdown":"https://insights.sbomify.com/CVE-2026-62654/index.md","name":"CVE-2026-62654","record":{"aliases":["GHSA-gq4w-8jx8-2hcg"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"adjacent_or_local","non_default_config":true,"product_category":"Siemens Reyrolle relay","requires_auth":"none","summary":"An attacker with physical access can trigger maintenance mode to execute arbitrary unsigned code from a network server on Siemens Reyrolle relays.","user_interaction":"not_required","vuln_class":"code_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[],"cvss":{"score":7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-494","name":"Download of Code Without Integrity Check"}],"description":"A vulnerability has been identified in Reyrolle 7SR5 (All versions \u003c V2.70). A special maintenance mode can be activated via a physical key sequence during device boot, in which the device downloads and executes program code from a network server without verifying its authenticity or integrity. This could allow an attacker with physical access to the device to upload and execute arbitrary, unsigned code.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Code injection in Reyrolle 7SR5","id":"CVE-2026-62654","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"code_injection","year":"2026"},"n_packages":0,"n_references":1,"next":{"headline":"A DoS vulnerability due to stack overflow exists in certain NETGEAR Orbi models","id":"CVE-2026-62655"},"packages":[],"prev":{"headline":"Memory corruption in Reyrolle 7SR5","id":"CVE-2026-62653"},"products":["Reyrolle 7SR5"],"published":"2026-09-08","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-09-08","vendors":["Siemens"]},"summary":"An attacker with physical access can trigger maintenance mode to execute arbitrary unsigned code from a network server on Siemens Reyrolle relays.","url":"https://insights.sbomify.com/CVE-2026-62654/"}