{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2026-6865 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-6865 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-6865 is a high-severity path traversal vulnerability in Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit \u0026 Controller, published on 12 May 2026. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-6865 and fix it if it is affected.\n\nWhat it is: CVE-2026-6865 is a high-severity path traversal vulnerability in Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit \u0026 Controller, published on 12 May 2026. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2026-6865 in the wild and no public exploit code.\n\nAffected product: Schneider Electric EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit \u0026 Controller. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-6865/ (Markdown: https://insights.sbomify.com/CVE-2026-6865/index.md)","id":"CVE-2026-6865","markdown":"https://insights.sbomify.com/CVE-2026-6865/index.md","name":"CVE-2026-6865","record":{"aliases":["GHSA-m738-m34q-2xgp"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Schneider Electric RTU","requires_auth":"low_privilege","summary":"Attackers can access sensitive files via path traversal in Schneider Electric remote terminal units, requiring vendor patches.","user_interaction":"not_required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[],"cvss":{"score":7.1,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-22","name":"Improper Limitation of a Pathname to a Restricted Directory"}],"description":"CWE-22: Improper Limitation of a Pathname to a Restricted Directory (“Path Traversal”) vulnerability that could cause unauthorized access to sensitive files when user-supplied input is improperly handled during server-side file path processing.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Improper Limitation of a Pathname to a Restricted Directory Vulnerability on Multiple Products","id":"CVE-2026-6865","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2026"},"n_packages":0,"n_references":1,"next":{"headline":"Initialization of a Resource with an Insecure Default vulnerability on EcoStruxure™ Panel Server","id":"CVE-2026-6866"},"packages":[],"prev":{"headline":"CBX 5 Star Rating \u0026 Review \u003c= 1.0.7 - Reflected Cross-Site Scripting via 'page' Parameter","id":"CVE-2026-6864"},"products":["EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit \u0026 Controller","Saitel DP Remote Terminal Unit \u0026 Controller"],"published":"2026-05-12","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-05-12","vendors":["Schneider Electric"]},"summary":"Attackers can access sensitive files via path traversal in Schneider Electric remote terminal units, requiring vendor patches.","url":"https://insights.sbomify.com/CVE-2026-6865/"}