{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2026-76749 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-76749 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-76749 is a medium-severity vulnerability in Hewlett Packard Enterprise (HPE) AOS-Switch (AOS-S), published on 6 Oct 2026. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-76749 and fix it if it is affected.\n\nWhat it is: CVE-2026-76749 is a medium-severity vulnerability in Hewlett Packard Enterprise (HPE) AOS-Switch (AOS-S), published on 6 Oct 2026. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2026-76749 in the wild and no public exploit code.\n\nAffected product: Hewlett Packard Enterprise (HPE) AOS-Switch (AOS-S). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-76749/ (Markdown: https://insights.sbomify.com/CVE-2026-76749/index.md)","id":"CVE-2026-76749","markdown":"https://insights.sbomify.com/CVE-2026-76749/index.md","name":"CVE-2026-76749","record":{"aliases":["GHSA-rjjv-xg7f-54c4"],"analysis":{"component_type":"network_device","fix_type":"patch","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"HPE AOS-Switch","requires_auth":"low_privilege","summary":"Unauthenticated remote attackers can access sensitive information on HPE AOS-Switch devices, requiring immediate patching.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"hpe","cpe":[],"cvss":{"score":6.5,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"description":"A sensitive information disclosure vulnerability exists in AOS-S. Successful exploitation could allow an unauthenticated remote attacker to access sensitive information.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Unauthenticated Sensitive Information Disclosure in AOS-S","id":"CVE-2026-76749","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2026"},"n_packages":0,"n_references":1,"next":{"headline":"Deserialization in ClearPass Policy Manager (CPPM)","id":"CVE-2026-76750"},"packages":[],"prev":{"headline":"Authenticated Privilege Escalation Vulnerability in the API of AOS-S","id":"CVE-2026-76748"},"products":["AOS-Switch (AOS-S)"],"published":"2026-10-06","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-10-07","vendors":["Hewlett Packard Enterprise (HPE)"]},"summary":"Unauthenticated remote attackers can access sensitive information on HPE AOS-Switch devices, requiring immediate patching.","url":"https://insights.sbomify.com/CVE-2026-76749/"}