{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2026-80172 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-80172 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-80172 is a critical authentication bypass vulnerability in Dell Secure Connect Gateway, published on 9 Sep 2026. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-80172 and fix it if it is affected.\n\nWhat it is: CVE-2026-80172 is a critical authentication bypass vulnerability in Dell Secure Connect Gateway, published on 9 Sep 2026. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2026-80172 in the wild and no public exploit code.\n\nAffected product: Dell Secure Connect Gateway. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-80172/ (Markdown: https://insights.sbomify.com/CVE-2026-80172/index.md)","id":"CVE-2026-80172","markdown":"https://insights.sbomify.com/CVE-2026-80172/index.md","name":"CVE-2026-80172","record":{"aliases":["GHSA-f8g2-6jhm-qr64"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["privilege_escalation","account_takeover"],"network_reachable":"yes","non_default_config":false,"product_category":"Secure Connect Gateway","requires_auth":"none","summary":"Unauthenticated attackers can reuse captured requests to gain admin access due to missing nonce validation, requiring an upgrade.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"dell","cpe":[{"product":"secure_connect_gateway","vendor":"dell"}],"cvss":{"score":9.8,"severity":"critical","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-345","name":"Insufficient Verification of Data Authenticity"}],"description":"Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Insufficient Verification of Data Authenticity vulnerability. An unauthenticated attacker with remote access could exploit this, leading to unauthorized access. This vulnerability is considered critical as an unauthenticated attacker can repeatedly reuse a captured request to generate ADMIN access and refresh tokens. Since there is no nonce validation or time limit on requests, the attack can be performed indefinitely. Dell recommends customers to upgrade at the earliest opportunity","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Auth bypass in Secure Connect Gateway 5.0 - Appliance","id":"CVE-2026-80172","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"dell:secure_connect_gateway","products":["dell:secure_connect_gateway"],"type":"auth_bypass","year":"2026"},"n_packages":0,"n_references":1,"next":{"headline":"Security feature bypass in Secure Connect Gateway 5.0 - Appliance","id":"CVE-2026-80174"},"packages":[],"prev":{"headline":"Weak cryptography in Secure Connect Gateway 5.0 - Appliance","id":"CVE-2026-80171"},"products":["Secure Connect Gateway 5.0 - Appliance","Secure Connect Gateway 5.0 - Application"],"published":"2026-09-09","related":[{"cvss_score":9.4,"headline":"Missing authorization in Secure Connect Gateway 5.0 - Appliance","id":"CVE-2026-61410","kev_date_added":null,"published":"2026-09-07"},{"cvss_score":9.3,"headline":"Privilege escalation in Secure Connect Gateway 5.0 - Appliance","id":"CVE-2026-80238","kev_date_added":null,"published":"2026-09-07"},{"cvss_score":8.2,"headline":"Security feature bypass in Secure Connect Gateway 5.0 - Appliance","id":"CVE-2026-78491","kev_date_added":null,"published":"2026-09-09"},{"cvss_score":8.2,"headline":"Missing authorization in Secure Connect Gateway 5.0 - Appliance","id":"CVE-2026-79645","kev_date_added":null,"published":"2026-09-07"},{"cvss_score":8.1,"headline":"Missing authorization in Secure Connect Gateway 5.0 - Appliance","id":"CVE-2026-80132","kev_date_added":null,"published":"2026-09-07"},{"cvss_score":7.8,"headline":"Privilege escalation in Secure Connect Gateway 5.0 - Appliance","id":"CVE-2026-80166","kev_date_added":null,"published":"2026-09-07"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-09-11","vendors":["Dell"]},"summary":"Unauthenticated attackers can reuse captured requests to gain admin access due to missing nonce validation, requiring an upgrade.","url":"https://insights.sbomify.com/CVE-2026-80172/"}