{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2026-80276 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-80276 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-80276 is a high-severity vulnerability in Comelit Group S.p.A. 1456B Multi-User Gateway, published on 1 Oct 2026. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-80276 and fix it if it is affected.\n\nWhat it is: CVE-2026-80276 is a high-severity vulnerability in Comelit Group S.p.A. 1456B Multi-User Gateway, published on 1 Oct 2026. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2026-80276 in the wild and no public exploit code.\n\nAffected product: Comelit Group S.p.A. 1456B Multi-User Gateway. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-80276/ (Markdown: https://insights.sbomify.com/CVE-2026-80276/index.md)","id":"CVE-2026-80276","markdown":"https://insights.sbomify.com/CVE-2026-80276/index.md","name":"CVE-2026-80276","record":{"aliases":["GHSA-g5xq-fc7g-hgv3"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["data_read","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Comelit Multi-User Gateway","requires_auth":"none","summary":"Unauthenticated attackers can read sensitive configuration data, including passwords, from the Comelit 1456B gateway's management interface.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"NCSC-FI","cpe":[],"cvss":{"score":7.5,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"description":"Comelit Multi-User Gateway for VIP System (model 1456B) firmware versions 2.9.1 and 2.10.0 expose a network-accessible management interface that does not require authentication. Through this interface, sensitive device configuration data - including the Remote Configuration Password - can be read in cleartext by a remote, unauthenticated attacker.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Comelit 1456B gateway exposes remote configuration password via unauthenticated management interface","id":"CVE-2026-80276","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2026"},"n_packages":0,"n_references":2,"next":{"headline":"SQL Injection in HAVELSAN's Sef - AI Chatbot Platform","id":"CVE-2026-80298"},"packages":[],"prev":{"headline":"Comelit 1456B gateway allows low priviledge user to overwrite installer password via unauthorized endpoint","id":"CVE-2026-80275"},"products":["1456B Multi-User Gateway"],"published":"2026-10-01","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-10-05","vendors":["Comelit Group S.p.A."]},"summary":"Unauthenticated attackers can read sensitive configuration data, including passwords, from the Comelit 1456B gateway's management interface.","url":"https://insights.sbomify.com/CVE-2026-80276/"}