{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2026-80358 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-80358 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-80358 is a medium-severity authentication bypass vulnerability in Dell Boot Optimized Server Storage (BOSS), published on 28 Sep 2026. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2026-80358 and fix it if it is affected.\n\nWhat it is: CVE-2026-80358 is a medium-severity authentication bypass vulnerability in Dell Boot Optimized Server Storage (BOSS), published on 28 Sep 2026. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2026-80358 in the wild and no public exploit code.\n\nAffected product: Dell Boot Optimized Server Storage (BOSS). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-80358/ (Markdown: https://insights.sbomify.com/CVE-2026-80358/index.md)","id":"CVE-2026-80358","markdown":"https://insights.sbomify.com/CVE-2026-80358/index.md","name":"CVE-2026-80358","record":{"aliases":["GHSA-5g2v-763c-c88m"],"analysis":{"component_type":"hardware_firmware","fix_type":"upgrade","impacts":["security_bypass"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Dell BOSS controller","requires_auth":"none","summary":"An unauthenticated attacker with physical access can bypass access controls on Dell BOSS controllers via the SMCU debug interface.","user_interaction":"required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"dell","cpe":[],"cvss":{"score":5.1,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:P/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:L","version":"3.1"},"cwes":[{"id":"CWE-1191","name":"On-Chip Debug and Test Interface With Improper Access Control"}],"description":"Dell Boot Optimized Server Storage (BOSS), versions prior to 2.2.13.2038, contains an On-Chip Debug and Test Interface With Improper Access Control vulnerability in the SMCU on 17G BOSS-N1 controllers. An unauthenticated attacker with physical access could potentially exploit this vulnerability, leading to Unauthorized access.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Auth bypass in Boot Optimized Server Storage (BOSS)","id":"CVE-2026-80358","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2026"},"n_packages":0,"n_references":1,"next":{"headline":"Auth bypass in Boot Optimized Server Storage (BOSS)","id":"CVE-2026-80359"},"packages":[],"prev":{"headline":"Auth bypass in Boot Optimized Server Storage (BOSS)","id":"CVE-2026-80357"},"products":["Boot Optimized Server Storage (BOSS)"],"published":"2026-09-28","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-09-28","vendors":["Dell"]},"summary":"An unauthenticated attacker with physical access can bypass access controls on Dell BOSS controllers via the SMCU debug interface.","url":"https://insights.sbomify.com/CVE-2026-80358/"}