{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2026-8265 exists.","fix":"No fix has been published for CVE-2026-8265 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-8265 is a medium-severity command injection vulnerability in Tenda Ac6 Firmware, published on 11 May 2026. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-8265 and fix it if it is affected.\n\nWhat it is: CVE-2026-8265 is a medium-severity command injection vulnerability in Tenda Ac6 Firmware, published on 11 May 2026. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2026-8265 exists.\n\nAffected product: Tenda Ac6 Firmware. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-8265/ (Markdown: https://insights.sbomify.com/CVE-2026-8265/index.md)","id":"CVE-2026-8265","markdown":"https://insights.sbomify.com/CVE-2026-8265/index.md","name":"CVE-2026-8265","record":{"aliases":["GHSA-qvqp-rwfh-7f5j"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Tenda AC6 router","requires_auth":"high_privilege","summary":"Remote attackers can execute arbitrary OS commands on Tenda AC6 routers via the getLogFile interface, requiring authentication.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulDB","cpe":[{"product":"ac6_firmware","vendor":"tenda"}],"cvss":{"score":5.1,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P","version":"4.0"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"},{"id":"CWE-77","name":"Improper Neutralization of Special Elements used in a Command"}],"description":"A security vulnerability has been detected in Tenda AC6 15.03.06.23. Affected by this issue is the function get_log_file of the file /goform/getLogFile of the component httpd. The manipulation of the argument wans.flag leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Tenda AC6 httpd getLogFile get_log_file os command injection","id":"CVE-2026-8265","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"tenda:ac6_firmware","products":["tenda:ac6_firmware"],"type":"command_injection","year":"2026"},"n_packages":0,"n_references":5,"next":{"headline":"Open5GS SMF gsm-build.c gsm_build_pdu_session_establishment_accept denial of service","id":"CVE-2026-8266"},"packages":[],"prev":{"headline":"Tenda AC6 httpd WifiApScan formWifiApScan os command injection","id":"CVE-2026-8264"},"products":["AC6"],"published":"2026-05-11","related":[{"cvss_score":9.8,"headline":"Auth bypass in AC6 V5.0","id":"CVE-2025-27129","kev_date_added":null,"published":"2025-08-20"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-29029","kev_date_added":null,"published":"2025-03-14"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-29030","kev_date_added":null,"published":"2025-03-14"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-29031","kev_date_added":null,"published":"2025-03-14"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2025-25343","kev_date_added":null,"published":"2025-02-12"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2023-40830","kev_date_added":null,"published":"2023-10-03"},{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2023-40837","kev_date_added":null,"published":"2023-08-30"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"poc","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-05-11","vendors":["Tenda"]},"summary":"Remote attackers can execute arbitrary OS commands on Tenda AC6 routers via the getLogFile interface, requiring authentication.","url":"https://insights.sbomify.com/CVE-2026-8265/"}