{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2026-85384 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-85384 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-85384 is a high-severity memory corruption vulnerability in TP-Link Systems Inc. RE210 AC750, published on 8 Sep 2026. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-85384 and fix it if it is affected.\n\nWhat it is: CVE-2026-85384 is a high-severity memory corruption vulnerability in TP-Link Systems Inc. RE210 AC750, published on 8 Sep 2026. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2026-85384 in the wild and no public exploit code.\n\nAffected product: TP-Link Systems Inc. RE210 AC750. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-85384/ (Markdown: https://insights.sbomify.com/CVE-2026-85384/index.md)","id":"CVE-2026-85384","markdown":"https://insights.sbomify.com/CVE-2026-85384/index.md","name":"CVE-2026-85384","record":{"aliases":["GHSA-j5wp-3x5f-9h6c"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution","privilege_escalation"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Wi-Fi range extender","requires_auth":"high_privilege","summary":"An authenticated attacker can trigger a stack-based buffer overflow via a crafted configuration file, leading to remote code execution on the device.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"TPLink","cpe":[],"cvss":{"score":8.5,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-121","name":"Stack-based Buffer Overflow"}],"description":"A stack-based buffer overflow vulnerability exists in the httpd component of RE210 AC750 due to improper bounds checking in the splitString function when processing an uploaded configuration file. An authenticated attacker on the local network can upload a crafted configuration file to trigger the overflow, leading to remote code execution.\n\nSuccessful exploitation may allow unauthorized access to sensitive information, modification of device configuration and network behavior, or disruption of device availability.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Authenticated Stack-Based Buffer Overflow in RE210 AC750 Configuration Import","id":"CVE-2026-85384","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2026"},"n_packages":0,"n_references":1,"next":{"headline":"Concrete CMS below 9.5.4 is vulnerable to Stored XSS via User Timezone Field","id":"CVE-2026-85385"},"packages":[],"prev":{"headline":"itsourcecode Sales and Inventory System inv_del.php sql injection","id":"CVE-2026-85383"},"products":["RE210 AC750"],"published":"2026-09-08","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-09-10","vendors":["TP-Link Systems Inc."]},"summary":"An authenticated attacker can trigger a stack-based buffer overflow via a crafted configuration file, leading to remote code execution on the device.","url":"https://insights.sbomify.com/CVE-2026-85384/"}