{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2026-85628 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-85628 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-85628 is a high-severity vulnerability in Fermax Electronica S.A.U. DUOX PLUS monitor firmware (VEO Wi-Fi range), published on 16 Sep 2026. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2026-85628 and fix it if it is affected.\n\nWhat it is: CVE-2026-85628 is a high-severity vulnerability in Fermax Electronica S.A.U. DUOX PLUS monitor firmware (VEO Wi-Fi range), published on 16 Sep 2026. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2026-85628 in the wild and no public exploit code.\n\nAffected product: Fermax Electronica S.A.U. DUOX PLUS monitor firmware (VEO Wi-Fi range). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-85628/ (Markdown: https://insights.sbomify.com/CVE-2026-85628/index.md)","id":"CVE-2026-85628","markdown":"https://insights.sbomify.com/CVE-2026-85628/index.md","name":"CVE-2026-85628","record":{"aliases":["GHSA-mmjj-x36j-f536"],"analysis":{"component_type":"iot_embedded","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"VEO Wi-Fi monitor","requires_auth":"none","summary":"An attacker on the Wi-Fi Direct network can intercept home Wi-Fi credentials transmitted in cleartext during the pairing process between the DuoxMe app and VEO monitors.","user_interaction":"required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"FERMAX","cpe":[],"cvss":{"score":7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:P/VC:H/VI:N/VA:N/SC:H/SI:L/SA:N","version":"4.0"},"cwes":[{"id":"CWE-319","name":"Cleartext Transmission of Sensitive Information"}],"description":"Transmission of the home Wi-Fi credentials without encryption during the pairing process between the DuoxMe application and VEO and VEO-XS Wi-Fi monitors, in versions prior to 4.3.4 of the application and 01.50.001 of the monitor firmware, allows an attacker on the Wi-Fi Direct network to intercept the network password.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cleartext Transmission of Sensitive Information in the Pairing Process vulnerability","id":"CVE-2026-85628","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2026"},"n_packages":0,"n_references":1,"next":{"headline":"HTML::FormHandler versions before 0.410002 for Perl render field attributes into HTML without escaping using the process_attrs method.","id":"CVE-2026-85630"},"packages":[],"prev":{"headline":"git-mcp-server 2.15.1 Argument Injection via Git Ref Parameters","id":"CVE-2026-85626"},"products":["DUOX PLUS monitor firmware (VEO Wi-Fi range)","DuoxMe"],"published":"2026-09-16","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-09-16","vendors":["Fermax Electronica S.A.U."]},"summary":"An attacker on the Wi-Fi Direct network can intercept home Wi-Fi credentials transmitted in cleartext during the pairing process between the DuoxMe app and VEO monitors.","url":"https://insights.sbomify.com/CVE-2026-85628/"}