{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2026-89208 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-89208 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-89208 is a medium-severity memory corruption vulnerability in Siemens Capital Embedded AR Classic 431-422, published on 13 Oct 2026. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-89208 and fix it if it is affected.\n\nWhat it is: CVE-2026-89208 is a medium-severity memory corruption vulnerability in Siemens Capital Embedded AR Classic 431-422, published on 13 Oct 2026. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2026-89208 in the wild and no public exploit code.\n\nAffected product: Siemens Capital Embedded AR Classic 431-422. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-89208/ (Markdown: https://insights.sbomify.com/CVE-2026-89208/index.md)","id":"CVE-2026-89208","markdown":"https://insights.sbomify.com/CVE-2026-89208/index.md","name":"CVE-2026-89208","record":{"aliases":["GHSA-3f9v-63rg-527j"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["data_read","denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens building automation","requires_auth":"none","summary":"Unauthenticated remote attackers can trigger out-of-bounds memory reads in Siemens building automation devices, potentially exposing sensitive data or causing service disruption.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[],"cvss":{"score":6.9,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-125","name":"Out-of-bounds Read"}],"description":"A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303), Desigo PXC00-E.D (All versions \u003e= V2.3), Desigo PXC00-U (All versions \u003e= V2.3), Desigo PXC001-E.D (All versions \u003e= V2.3), Desigo PXC100-E.D (All versions \u003e= V2.3), Desigo PXC12-E.D (All versions \u003e= V2.3), Desigo PXC128-U (All versions \u003e= V2.3), Desigo PXC200-E.D (All versions \u003e= V2.3), Desigo PXC22-E.D (All versions \u003e= V2.3), Desigo PXC22.1-E.D (All versions \u003e= V2.3), Desigo PXC36.1-E.D (All versions \u003e= V2.3), Desigo PXC50-E.D (All versions \u003e= V2.3), Desigo PXC64-U (All versions \u003e= V2.3), Desigo PXM20-E (All versions \u003e= V2.3). The affected product does not properly validate input bounds before accessing packet data. This could allow an unauthenticated remote attacker to trigger memory reads outside the intended packet boundaries.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Memory corruption in Capital Embedded AR Classic 431-422","id":"CVE-2026-89208","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2026"},"n_packages":0,"n_references":2,"next":{"headline":"A vulnerability has been identified in Mendix SAML (Mendix 10 compatible) (All versions \u003c V4.2.4), Mendix SAML (Mendix 11 compatible) (All v","id":"CVE-2026-89209"},"packages":[],"prev":{"headline":"Denial of service in WTV676-HB6035 Web Interface","id":"CVE-2026-89207"},"products":["Capital Embedded AR Classic 431-422","Capital Embedded AR Classic R20-11","Desigo PXC00-E.D","Desigo PXC00-U","Desigo PXC001-E.D","Desigo PXC100-E.D","Desigo PXC12-E.D","Desigo PXC128-U","Desigo PXC200-E.D","Desigo PXC22-E.D","Desigo PXC22.1-E.D","Desigo PXC36.1-E.D","Desigo PXC50-E.D","Desigo PXC64-U","Desigo PXM20-E"],"published":"2026-10-13","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-10-13","vendors":["Siemens"]},"summary":"Unauthenticated remote attackers can trigger out-of-bounds memory reads in Siemens building automation devices, potentially exposing sensitive data or causing service disruption.","url":"https://insights.sbomify.com/CVE-2026-89208/"}