{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2026-9633 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-9633 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-9633 is a high-severity vulnerability in Rockwell Automation Redundancy Module Configuration Tool, published on 1 Sep 2026. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2026-9633 and fix it if it is affected.\n\nWhat it is: CVE-2026-9633 is a high-severity vulnerability in Rockwell Automation Redundancy Module Configuration Tool, published on 1 Sep 2026. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2026-9633 in the wild and no public exploit code.\n\nAffected product: Rockwell Automation Redundancy Module Configuration Tool. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-9633/ (Markdown: https://insights.sbomify.com/CVE-2026-9633/index.md)","id":"CVE-2026-9633","markdown":"https://insights.sbomify.com/CVE-2026-9633/index.md","name":"CVE-2026-9633","record":{"aliases":["GHSA-f94w-8wrq-px55"],"analysis":{"component_type":"desktop_application","fix_type":"patch","impacts":["privilege_escalation","code_execution"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Redundancy Module Config Tool","requires_auth":"low_privilege","summary":"Local attackers can escalate privileges to Administrator by placing a malicious DLL in a writable path directory loaded by the configuration tool.","user_interaction":"required","vuln_class":"privilege_escalation"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Rockwell","cpe":[],"cvss":{"score":7,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-276","name":"Incorrect Default Permissions"}],"description":"A security issue exists within the Redundancy Module Configuration Tool. The RM3ConfigTool.exe binary searches directories in the system path for a required DLL, and one or more of these directories may be writable by standard (non-administrator) users due to incorrect default permissions. If a local attacker places a malicious DLL in such a directory and an administrator subsequently runs the tool, the malicious DLL is loaded into the elevated process and executes with Administrator/SYSTEM privileges.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Redundancy Module Configuration Tool - Multiple Vulnerabilities","id":"CVE-2026-9633","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"privilege_escalation","year":"2026"},"n_packages":0,"n_references":1,"next":{"headline":"Redundancy Module Configuration Tool - Multiple Vulnerabilities","id":"CVE-2026-9634"},"packages":[],"prev":{"headline":"UTT HiPER 1250GW Web Management formGroupConfig strcpy stack-based overflow","id":"CVE-2026-9632"},"products":["Redundancy Module Configuration Tool"],"published":"2026-09-01","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-09-01","vendors":["Rockwell Automation"]},"summary":"Local attackers can escalate privileges to Administrator by placing a malicious DLL in a writable path directory loaded by the configuration tool.","url":"https://insights.sbomify.com/CVE-2026-9633/"}