{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2026-9717 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2026-9717 yet. Limit exposure of the affected software until one is available.","what":"CVE-2026-9717 is a high-severity command injection vulnerability in Schneider Electric PowerLogic™ P7, published on 25 Jun 2026. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2026-9717 and fix it if it is affected.\n\nWhat it is: CVE-2026-9717 is a high-severity command injection vulnerability in Schneider Electric PowerLogic™ P7, published on 25 Jun 2026. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2026-9717 in the wild and no public exploit code.\n\nAffected product: Schneider Electric PowerLogic™ P7. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2026-9717/ (Markdown: https://insights.sbomify.com/CVE-2026-9717/index.md)","id":"CVE-2026-9717","markdown":"https://insights.sbomify.com/CVE-2026-9717/index.md","name":"CVE-2026-9717","record":{"aliases":["GHSA-47f2-rprg-7x63"],"analysis":{"component_type":"iot_embedded","fix_type":"patch","impacts":["code_execution","privilege_escalation"],"network_reachable":"yes","non_default_config":false,"product_category":"PowerLogic P7","requires_auth":"high_privilege","summary":"Privileged authenticated users can execute arbitrary OS commands with elevated privileges on Schneider Electric PowerLogic P7 devices.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"powerlogic_p7_firmware","vendor":"schneider-electric"}],"cvss":{"score":8.6,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"}],"description":"CWE-78 Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow unauthorized execution of commands with elevated privileges, impacting system integrity, confidentiality, and availability when a privileged authenticated user interacts with a vulnerable network-exposed service.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Command injection in PowerLogic™ P7","id":"CVE-2026-9717","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2026"},"n_packages":0,"n_references":1,"next":{"headline":"Denial of service in PowerLogic™ P7","id":"CVE-2026-9718"},"packages":[],"prev":{"headline":"Null dereference in PowerLogic™ P7","id":"CVE-2026-9716"},"products":["PowerLogic™ P7"],"published":"2026-06-25","related":[{"cvss_score":8.7,"headline":"Null dereference in PowerLogic™ P7","id":"CVE-2026-9716","kev_date_added":null,"published":"2026-06-25"},{"cvss_score":6.9,"headline":"Denial of service in PowerLogic™ P7","id":"CVE-2026-9718","kev_date_added":null,"published":"2026-06-25"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-06-25","vendors":["Schneider Electric"]},"summary":"Privileged authenticated users can execute arbitrary OS commands with elevated privileges on Schneider Electric PowerLogic P7 devices.","url":"https://insights.sbomify.com/CVE-2026-9717/"}